Skip to content
← Back to the blog

Avoiding resonance: finding it is not enough, judge it

Published

In the article on modal and harmonic analysis I described a tube whose first bending frequency (18 Hz) sat dangerously close to the drive excitation at idle. A modal analysis will find a match like that. The harder question comes straight afterwards: what do you do about it? Does it need a response at all — and if so, which one?

Every structure has plenty of resonances, and the excitation has plenty of order components. If every match between a frequency and the excitation were a problem, nothing could ever be designed. Telling the ones that genuinely matter from the ones that can be ignored is the core of this task.

Not every match is a problem — four factors of criticality

A match between a natural frequency and an excitation order is a necessary, not a sufficient condition. The excitation order — call it NN — says how many times per revolution the source excites: once at N=1N = 1, three times at N=3N = 3. The excitation frequency is then NN times the shaft speed. How the orders are read and where they cross the natural frequencies is covered in the article on the Campbell diagram.

Whether a resonance really is critical is decided by a product of several factors — and if even one of them is small, the product is small:

  1. Match with the excitation band. The natural frequency has to fall inside the band that the excitation actually sweeps through over the operating speed range. Outside that band there is nothing to excite it. A frequency match also needs a shape match: an excitation with a different symmetry from the mode shape will not drive it even when the frequency fits (more on that in the section on SAFE diagrams there).
  2. Strength of the excitation order. The excitation has several order components and they are not equally strong. Which order dominates is set by the source — it corresponds to the number of identical events or features per revolution, for example the number of firings, blades or teeth. Its higher harmonic multiples tend to be weaker. In our case the second order dominates.
  3. Dwell time. Steady operating points — idle, for instance, which is where f1 sits — keep a resonance active for a long time; a brief pass through it during run-up and run-down puts few cycles into the structure.
  4. Magnitude of the response. The decisive factor on the structure's side — how much the component really vibrates under the given excitation. A harmonic analysis gives us this. A stiff higher mode may show an order-of-magnitude smaller amplitude under the same excitation, so even with the frequencies matching its contribution is small.

The consequence is, in the end, fatigue — and the mean stress at the location in question enters there too (idle tends to be unloaded, operation loaded): a high tensile mean stress lowers the allowable alternating amplitude. [1]

So “the frequency matches the excitation” says nothing on its own. The tube showed that clearly: its second resonance (72 Hz) has both a band match and an excitation order, but its response is an order of magnitude weaker — only around three per cent of the idle value according to the harmonic analysis. One small factor and the product collapses; which is why we do not treat it as critical, even though it “fits” in frequency.

Two panels of bar charts showing criticality as a product of factors. On the left, f1 at idle: four tall bars (match, order strength, dwell time, response magnitude) and a tall resulting product, verdict critical. On the right, f3 in operation: match, order and time are all tall, but the response magnitude is almost nil, so the resulting product is negligible, verdict tolerable. Bar heights are schematic.

Criticality is a product of factors, not a yes/no (schematic). At f1 (idle) they are all high → critical. At f3 (operation) the frequency and the excitation both fit, but the response is weak — one small factor and the product collapses, so the resonance is tolerable.

A hierarchy of solutions

When a resonance really is critical, the options are the following, in order from the best to the last resort:

  1. Avoid it. Design the natural frequencies so that they lie outside every excitation band. The cleanest route, but not always feasible — there tend to be several bands and the structure is tied down by other requirements.
  2. Detune it. If avoidance is not possible globally, move the particular frequency out of the band by changing stiffness or mass.
  3. Tolerate it. If the response is weak and the fatigue check with mean stress passes, we can live with the resonance — but backed by calculation, not by estimate.
  4. Damp it. Add damping. The last choice, and I explain why below.

In industry — rotating machinery especially — the first step is often formalised as a separation margin: natural frequencies are kept a certain distance away from the excitation. The API rotordynamic tutorial (TR 684-1) quotes a margin of the order of 10 % for torsional natural frequencies. For lateral critical speeds there is no fixed percentage: the required margin depends on the amplification factor of the resonance — the sharper the peak, the larger the margin, and for a sufficiently damped peak (amplification factor below 2.5) no margin is required. Where the margin cannot be met, a forced-response analysis steps in — that is, the backed-up tolerating mentioned above. Our hierarchy is the same thing, only expressed through the response instead of a fixed percentage. [2]

Detuning: moving the frequency away

Detuning rests on a single relation. For a simple oscillating system,

f=12πkm,f = \frac{1}{2\pi}\sqrt{\frac{k}{m}},

where kk is the stiffness and mm the mass. [3] Two levers follow from it: higher stiffness raises the frequency, added mass lowers it. The excitation does not need changing — it is enough to shift the structure's natural frequency so that it lies somewhere other than the excitation band.

On the tube this turned out to be interesting. The composite overbraid added stiffness (which buckling demanded) but also mass. For the first frequency the mass effect won: f1 moved lower, that is, further still from the drive excitation at idle, which lay above it. The reason was the fibre angle: at ±45° carbon has a modulus of only about 9.3 GPa along the tube axis, so the braid adds relatively little bending stiffness but a noticeable amount of mass. Counter-intuitive — the heavier tube is the safer one here — but that is exactly what the relation above says.

A frequency axis with the drive excitation band at idle marked on it. In the state before the modification the first natural frequency sits just below the band, dangerously close. After mass is added the frequency moves left, away from the band, to a safe margin. An arrow shows the frequency shifting downwards.

Detuning: the excitation band does not move. Added mass shifts the natural frequency away from it. Not always downwards — if the excitation lay below the frequency, the answer would be extra stiffness, which raises it.

Detuning also has a ceiling. For the higher modes f3 and f5, beyond a braid length of about 1200 mm and six plies the frequency practically stops moving — further material only adds mass. How far to go and how much material to add is not a single number but a region of compromise; that is handled by a separate article on multi-objective optimisation.

When avoidance is impossible — tolerating it, with proof

Some resonances cannot be pulled out of the band by any sensible modification. The second bending frequency of the tube (72 Hz) stayed inside the operating band for every braid variant — it moved, but it never got out. We still do not treat it as critical, because its response was an order of magnitude weaker than the one at idle.

That is a legitimate third step: tolerate it, but with proof. The proof is not that the analysis ran, but a harmonic analysis (how large the response is) and a fatigue check (the alternating amplitude together with the mean stress, via a Goodman–Haigh diagram, for example [1]). Without those, this solution is not backed up — it is just hoping. For the tube the first part is satisfied; the fatigue check will follow once the real excitation has been measured, and until then we tolerate f3 on the basis of its response.

And why is damping only the last step? Not because it does not work — at resonance it is the only thing holding the amplitude down, and ten times the damping cuts the peak by roughly a factor of ten. But it does not remove the problem, it only reduces it: the resonance stays inside the operating band and the response grows directly with the excitation, which we do not know without measurement. On top of that, damping is the hardest of the three quantities to estimate and to guarantee — in a metal structure it comes mostly from joints and contact faces, and for add-on elements it depends on temperature, frequency and ageing, whereas stiffness and mass are geometry that a model handles reliably. And a damper has to be built in somewhere: material, a mounting, an extra part. That is why avoiding a resonance or detuning it is usually both cheaper and more reliable than damping it out. [4][5]

Summary

For the tube it ended up like this: the idle resonance (f1) had to be dealt with, and the braid dealt with it by detuning — added mass moved the frequency away from the excitation. The operating resonance f3 could not be pulled out of the band, but its response was weak, so for now we tolerate it — the fatigue check after the excitation has been measured will confirm that. No damping was needed.

The procedure is always the same: find the resonances (modal analysis), judge them (the product of factors, where the magnitude of the response from a harmonic analysis decides it) and only then act — in the order avoid, detune, tolerate, damp. Where the resonances arise and at what speeds can be read off a Campbell diagram, which the next article is devoted to.

If you are working on a similar complex problem — a component that vibrates or is noisy in a particular regime — do feel free to get in touch.

Sources

  1. Shigley, J. E., Budynas, R. G., Nisbett, J. K. Shigley's Mechanical Engineering Design, McGraw-Hill (fatigue, mean stress, the Goodman–Haigh diagram).
  2. API TR 684-1 (formerly API RP 684), API Standard Paragraphs Rotordynamic Tutorial: Lateral Critical Speeds, Unbalance Response, Stability, Train Torsionals, and Rotor Balancing, American Petroleum Institute.
  3. Rao, S. S. Mechanical Vibrations, Pearson.
  4. Den Hartog, J. P. Mechanical Vibrations, Dover Publications, 1985 (reprint of the 4th edition, McGraw-Hill, 1956).
  5. Harris, C. M., Piersol, A. G. (eds.) Harris' Shock and Vibration Handbook, 5th edition, McGraw-Hill, 2002.

Frequently asked questions

Is every match between a natural frequency and the excitation a problem?
No. A match is only a necessary condition. Criticality is a product of several factors: the match with the excitation band, the strength of the excitation order (an order is a multiple of the shaft speed at which the source excites), the dwell time, and above all the magnitude of the response from a harmonic analysis; for fatigue, the mean stress as well. If even one of those factors is small — say the response of a higher mode that the given excitation only weakly drives — the resonance is not critical, even though the frequency fits.
What does it mean to detune a resonance?
To move the natural frequency out of the excitation band by changing stiffness or mass. Since frequency is proportional to the square root of stiffness over mass, stiffness raises it and added mass lowers it. So the excitation need not change at all — it is enough to change the structure so that its natural frequency lies elsewhere. How far it moves depends on the location: mass added at an antinode of the given mode shape lowers it the most, mass at a node almost not at all.
Why does adding mass sometimes help against resonance?
Because mass lowers the natural frequency. When the excitation lies above the first natural frequency and that frequency is dangerously close to it, added mass pushes it lower still, further away from the excitation. It feels counter-intuitive — here the heavier structure is the safer one — but it follows directly from the relation between frequency, stiffness and mass.
When can a resonance simply be tolerated?
When its response is weak and the fatigue check with mean stress passes — and when a calculation backs that up rather than an estimate. Higher, stiffer modes often show an order-of-magnitude smaller amplitude under smooth, steady excitation, so even if you cannot pull the frequency out of the excitation band, the consequence may be negligible. The proof is a harmonic analysis and a fatigue check, not the fact that the analysis ran.
When is adding damping the right move?
As a last resort — not because it does not work. At light damping the resonant peak is proportional to 1/(2ζ), so doubling the damping roughly halves it. But it does not remove the resonance, only reduces it, and of the three quantities damping is the hardest one to estimate and to guarantee: it depends on joints, temperature and ageing, whereas stiffness and mass are geometry. That is why avoiding a resonance or detuning it is usually cheaper and more reliable.

Related articles